CAN/CSA-C22.2 NO. 1010.2.032-96 (R00)
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 2-032: Particular Requirements for Hand-Held Current Clamps for Electrical Measurement and Test (Adopted IEC 1010-2-032:1994 with modifications) / Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-032: Prescriptions particulières pour pinces ampèremétriques tenues à la main pour mesurage et essais électriques (norme CEI 1010-2-032:1994 adoptée, avec modifications)
SKU: 2411066
Published by CSA Group
Publication Year 1996
Reaffirmed in 2000
25 pages
Withdrawn
Product Details
Scope
This clause of part 1 is applicable, except as follows:
Replace the text by the following:
This International Standard applies to hand-held and hand- manipulated CURRENT CLAMPS. These CURRENT CLAMPS are for use in the measurement of current without interruption of the current path of the circuit in which it is measured. They may be stand- alone CURRENT CLAMPS which are themselves within the scope of part 1, or accessories to other equipment within the scope of part 1.
This standard does not apply to current transformers or current transducers intended for fixed installations.
1.4
Environmental conditions
Replace the seventh dash by the following:
- primary input circuits with transient overvoltages according to INSTALLATION CATEGORIES (OVERVOLTAGE CATEGORIES) I, II, III and IV (see annex J). /
Domaine d'application et objet
Cet article de la partie 1 est applicable, à l'exception de ce qui suit:
Remplacer le texte par le texte suivant:
La présente Norme internationale s'applique aux PINCES AMPÈREMÉTRIQUES tenues ou manipulées à la main. Ces PINCES AMPÈREMÉTRIQUES sont destinées au mesurage du courant dans le circuit mesuré sans interruption de ce circuit. Il peut s'agir de PINCES AMPÈREMÉTRIQUES simples entrant dans le domaine d'application de la parite 1, ou d'accessoires à d'autres a ppareils électriques entrant dans le domaine d'application de la partie 1.
Cette norme ne s'applique pas aux transformateurs de courant ni aux transducteurs de courant prévus pour des installations fixes.
1.4
Conditions d'environnement
Remplacer le septième tiret par le suivant:
- circuits d'entrée primaire à surtensions transitoires conformément aux CATÉGORIES D'INSTALLATION (CATÉGORIES DE SURTENSION ) I, II, III ET IV (voir annexe J).
This clause of part 1 is applicable, except as follows:
Replace the text by the following:
This International Standard applies to hand-held and hand- manipulated CURRENT CLAMPS. These CURRENT CLAMPS are for use in the measurement of current without interruption of the current path of the circuit in which it is measured. They may be stand- alone CURRENT CLAMPS which are themselves within the scope of part 1, or accessories to other equipment within the scope of part 1.
This standard does not apply to current transformers or current transducers intended for fixed installations.
1.4
Environmental conditions
Replace the seventh dash by the following:
- primary input circuits with transient overvoltages according to INSTALLATION CATEGORIES (OVERVOLTAGE CATEGORIES) I, II, III and IV (see annex J). /
Domaine d'application et objet
Cet article de la partie 1 est applicable, à l'exception de ce qui suit:
Remplacer le texte par le texte suivant:
La présente Norme internationale s'applique aux PINCES AMPÈREMÉTRIQUES tenues ou manipulées à la main. Ces PINCES AMPÈREMÉTRIQUES sont destinées au mesurage du courant dans le circuit mesuré sans interruption de ce circuit. Il peut s'agir de PINCES AMPÈREMÉTRIQUES simples entrant dans le domaine d'application de la parite 1, ou d'accessoires à d'autres a ppareils électriques entrant dans le domaine d'application de la partie 1.
Cette norme ne s'applique pas aux transformateurs de courant ni aux transducteurs de courant prévus pour des installations fixes.
1.4
Conditions d'environnement
Remplacer le septième tiret par le suivant:
- circuits d'entrée primaire à surtensions transitoires conformément aux CATÉGORIES D'INSTALLATION (CATÉGORIES DE SURTENSION ) I, II, III ET IV (voir annexe J).